HAVITAL AS-500



Anti-static Steel Concrete Raised Floor with HPL Finish
Constructed using high-quality deep stretch coil steel coated with epoxy powder, the Havital AS-500 is filled with foamed cement. It features a flat steel top sheet welded to a formed steel bottom sheet. This anti-static raised floor system is designed to prevent static electricity, ensuring the reliable performance of sensitive electronics.
Product Specifications
- Size: 600x600x35mm/610x610x35mm
- Materials: Steel, Cement
- Installation: Stringer System
- Finish: HPL
- Edging: Fold Edging / Cut Edging

System performance criteria are crucial as they reflect the floor’s performance in a typical installation. While panel-only criteria like concentrated load are often used to specify systems, they can be misleading. These tests are conducted with panel testing blocks, not the actual understructure, and may not represent real-world condition.
System Performance Criteria | ||||||
System Type | Static Loads | Rolling Loads | ||||
Test Type | Panel Size | Concentrated Load | Safety Factor (min.2.0) | Ultimated load | 10 Passes | 10,000 Passes |
FS800 | 600x600x35mm 610x610x35mm | 368kg/800lbs | Pass | 736kg/1600lbs | 318kg 700lbs | 275kg 600lbs |
FS1000 | 600x600x35mm 610x610x35mm | 454kg/1000lbs | Pass | 909kg/2000lbs | 368kg 800lbs | 318kg 700lbs |
FS1250 | 600x600x35mm 610x610x35mm | 568kg/1250lbs | Pass | 1136kg/2500lbs | 454kg 1000lbs | 368kg 800lbs |
FS1500 | 600x600x35mm 610x610x35mm | 681kg/1500lbs | Pass | 1363kg/3000lbs | 568kg 1250lbs | 454kg 1000lbs |
FS2000 | 600x600x35mm 610x610x35mm | 909kg/2000lbs | Pass | 1818kg/4000lbs | 681kg 1500lbs | 568kg 1250lbs |
FS2500 | 600x600x35mm 610x610x35mm | 1136kg/2500lbs | Pass | 2272kg/5000lbs | 909kg 2000lbs | 681kg 1500lbs |
FS3000 | 600x600x35mm 610x610x35mm | 1363kg/3000lbs | Pass | 2726kg/6000lbs | 1136kg 2500lbs | 909kg 2000lbs |
*A tests are performed using CISCA’s Recommend Test Procedures for Access Floors with the exception of Design Load
- Design Load:The design load of the raised access floor is tested using the CISCA Concentrated Load Test method on the actual understructure, rather than steel blocks. The design load is determined by taking the lower value between the ultimate load divided by two or the point at which permanent damage (yield point) begins to occur.
- Safety Factor: The safety factor for the raised access floor is the ratio of the design load to the ultimate load. International standards and Havital recommend a minimum safety factor of 2.
Steel Concrete Raised Floor Characteristics
Electrostatic Discharge Protection
Electrostatic Discharge (ESD) Protection effectively prevents the accumulation of static electricity, ensuring the safety and reliability of sensitive electronic equipment. By mitigating the risk of electrostatic discharge, it helps prevent potential damage to critical components in data centers, semiconductor manufacturing facilities, laboratories, and other high-tech environments where precision and uninterrupted operation are essential.

Excellent Load Performance
The Havital raised floor system is meticulously engineered to deliver exceptional load-bearing performance, ensuring durability and stability under heavy loads. Its robust construction makes it ideal for a wide range of applications, including commercial offices, data centers, industrial facilities, and high-traffic environments.

Class A Flame Spread & Smoke Developed Index
Havital Raised Floor meets high safety standards, ensuring excellent fire resistance with a Class A Flame Spread and Smoke Developed Index. This classification reflects its ability to minimize flame spread and smoke production, enhancing overall fire safety in commercial and high-occupancy environment

Convenient Maintenance
The powder-coated bare finish of the Havital SC Raised Floor is designed for convenient maintenance, ensuring effortless cleaning and long-term durability. Its smooth and resilient surface minimizes dust accumulation and simplifies routine upkeep, making it an ideal choice for high-traffic environments that require a low-maintenance flooring solution.
Dimensional Accuracy
Precision manufacturing ensures the dimensional accuracy of Havital Raised Floor panels, eliminating vibrations and guaranteeing a perfect fit. This meticulous craftsmanship enhances interchangeability, allowing seamless installation while maintaining superior stability, durability, and long-term performance.
Good Decoration
High-quality finishes and customizable designs ensure compatibility with various interior styles.
Steel Concrete Raised Floor Accessories
Rigid Panel Construction
Ensures a vibration-free, stable surface. Panels are precisely cut to fit permanent features and remain interchangeable for future modifications.
Anti-static HPL Finishes
High-Pressure Laminate (HPL) is a high-tech material designed for durability and impact resistance. Made under high pressure and temperature, it provides exceptional protection against scratches and wear while allowing for aesthetic flexibility.
Pedestals and Stringers
Necessary for installation, these components vary in specification depending on the flooring type. Contact us for personalized recommendations based on your project needs.
Other Accessories
Grommets, Outlet Boxes, and Electronic Sockets: These accessories facilitate wiring and routing for a more organized and functional workspace.
Glass Raised Floor Panels: Used in specific areas to monitor the situation under the raised floor, adding a layer of convenience and oversight.